Refrigeration Airconditioning by Lukim supreme systems Limited

  • Home
  • Kenya
  • Nairobi
  • Refrigeration Airconditioning by Lukim supreme systems Limited

Refrigeration Airconditioning  by Lukim supreme systems Limited All food / dairy products cold transport, storage cold rooms , freezers, chillers and ice generating equipment.

We supply, install,service and maintain all Refrigeration,Air conditioning and Mechanical ventilation systems tailored to your specific need and within your budget. We Audit / advise on existing installations for server rooms, BTS sites, data centers, telecom rooms, computer rooms, medical rooms, operation theaters, office and control rooms. All kitchen hoods, extract systems for lavatories and fresh air supply systems for low circulation spaces.

08/03/2021

Happy new year to all our esteemed customers and all those planning to sample our services.
Thank you for choosing us again in 2021. We promise to ensure that we shall continually provide you affordable solutions and the best value for your money.
Kindly get in touch with us for all Refrigeration,(cold rooms, freezer rooms, ice machines,etc), Air conditioning ( Car air con,Wall mount units, ceiling cassettes,Ducted blowers,VRF, Package Units etc.), Mechanical ventilation (Kitchen hoods,fresh air supply systems,extract systems,etc), Solar powered water Pumps, solar powered cold rooms/ air-conditioners, Battery Power back-up banks for home and office, Gypsum interiors, acoustic ceilings and furniture.
Get a free quotation now: 0724 785 386, 0731 468 292, [email protected] / [email protected]

Designing,building, installation, installation, testing , commissioning, trouble shooting of intergrated control panels ...
08/03/2021

Designing,building, installation, installation, testing , commissioning, trouble shooting of intergrated control panels for jet fans, smoke extraction, carbon monoxide sensing and extraction, fresh air supply . HVACR :Precision cooling redudancy intergration with fire alarm systems and timing, coldroom control panels.
ATS panels for generator- mains changeover.

07/12/2019

UK: A British company with a history of developing innovative “drop-in” refrigerants is set to introduce a zero-ODP, lower GWP, non-flammable replacement for R410A in existing air conditioning systems.

Designated R470A by ASHRAE, the R410A “drop-in” is one of two new patented, A1, non-flammable and non-toxic refrigerants to be introduced by Cheshire-based Refrigerant Solutions Ltd (RSL) in the new year. The other, its sister refrigerant R470B, offers similar benefits for the replacement of R404A and R507 in existing systems.
Problem

In the face of worldwide moves to phase-down HFC refrigerants, the refrigerant producers and system developers have come up with a number of interim and long-term, low and lower GWP solutions for most existing and new refrigeration applications.

Stationary air conditioning, however, and its use of R410A has proved more of a problem. R32 is becoming increasingly accepted in new systems, but its A2L flammability rating makes it currently unacceptable for larger VRF systems. Honeywell’s promised replacement R466A, although a non-flammable A1 alternative, will at least require the replacement of the condensing unit. So, until now there has been no acceptable lower GWP “drop-in” for existing systems. According to RSL, R470A might be the solution.

To be marketed by RSL as RS-53, R470A is a complicated blend of six recognised components. It combines HFOs with current HFCs and, unusually, the “natural” refrigerant CO2.

In addition to the relatively small amount of CO2, it blends the R410A components, R32 (17%) and R125 (19%), with R134a (7%), HFO1234ze(E) (44%) and a small amount of the less common HFC R227ea (3%).

These components give R470A a GWP of 909, higher than R32’s GWP of 675 and R466A’s 733, but significantly lower than the 2088 of R410A.

According to RSL, R470A has a similar thermodynamic performance to R410A with matching energy efficiency and cooling capacity. It is also said to be compatible with the materials commonly found in R410A equipment and its use in existing split systems would involve no changes to the hardware. It is also compatible with POE lubricants typically used in current R410A systems, avoiding the need for an oil change when retrofitting.

On the subject of glide, RSL technical manager Nick Poole admitted that engineers commonly viewed the glides of zeotropic refrigerants as a problem.

“While accepting that the difference between the dew and bubble points represents a comparative measure for the glides of different zeotropes, this value over-estimates the real evaporator glide, because flashing of the refrigerant in the expansion valve or cap tube reduces the glide.”

According to RSL, the misapprehension arises because a key effect has previously been ignored. This is that the refrigerant coil loops within the heat exchanger causing the refrigerant to flow in opposite directions in adjacent loops. As a result, the glide tends to be self-cancelling.

At an ambient temperature of 25ºC and air exit temperature achieved from the evaporator of around 12ºC, RS-53 has an intrinsic glide of 8K. According to RSL, this can be halved depending on the design of coil in the evaporator and has no detrimental effect on cooling the air compared to R410A. At an ambient temperature of 25ºC, the air exit temperature achieved from the evaporator of around 12ºC is similar to R410A, the company maintains.

120MW power plant cooling.....commissioned 5th Feb 2019. Marie gleta, Benin.
15/04/2019

120MW power plant cooling.....commissioned 5th Feb 2019. Marie gleta, Benin.

Address

Nairobi
40893-00100

Telephone

0724 785 386

Website

Alerts

Be the first to know and let us send you an email when Refrigeration Airconditioning by Lukim supreme systems Limited posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Share